1A2 Perform all the Quality Assurance / Batch or Lot Acceptance / Conformance / Initial Acceptance tests required of the manufacturer, as per the applicable section(s) of the material specification.
1A3 Flow and gel as per Test on Receipt Requirements
1A6 Shear as per Test on Receipt Requirements
1A8 Cure and tack free time as per Test on Receipt Requirements
1B2 Hardness as per Test on Receipt Requirements
1B7 Examine first 6 feet for tack and ease of unwind
1C4 Honeycomb node delamination
1C6 Resistance to drying and ageing
1D2 Specific gravity, water content, particle count, acid number, chlorine content
1D3 Condition in container, dry time, appearance
1D4 Dry time, appearance, gloss and color
1D7 Corrosion resistance (salt spray)
1D8 Condition in container, gloss, adhesion
1D9 Conductivity per application specification
1E8 Verify certificate of conformance
1F6 Application life, dry time and curve time
1F8 Tensile strength and modulus
1F9 Flexibility and knife test
1G5 Color, viscosity and application
1G6 Check for adequate propellant in aerosol container
1G7 Check that product is dry, powdery and contains no lumps
1G8 Check that, by spraying on a clean metal surface, product deposits evenly and smoothly
1G9 Test per MPS 212 Category 1
1H1 Test per MPS 212 Category 2
1H2 Test per MPS 212 Category 3
1H3 Test per MPS 212 Category 4
1H4 Test per MPS 212 Category 5
1H6 Strength at Standard Conditions
1H7 Check for a good fluidity and homogeneity by visual inspection.
1H8 Test per ASTM D2095. Perform the test using one aluminum rod of any alloy. Requirement: 1000 psi minimum. BLS 9403 specimens are permitted.
1H9 Cured hardness of MIL-A-46106
1J1 Glass Transition Temperature
1J6 Compression strength plus modulus calculations
1K4 Corrosion inhibiting characteristics, drying time
1K7 Quality and appearance, viscosity, pot life, dry time metal anchorage, fluid resistant (water 140°F only)
1L4 Quantitator inhibitor analysis
1L5 Fluid resistance per specification
1L6 Melt flow index per ASTM D1238
1L7 Flammability per specification
1M1 Flammability per specification
1M3 Melt flow index per ASTM D1238
1M4 Shear Strength and modulus
1M7 Lapshear A1/A1 Room Temperature, No Conditioning
1N6 Appearance -Homogeneous and Fluid in the Can
1N7 Tack and Tack Free Time per MPS 157-30
1N9 Tack Free Time 10 minutes at Room Temperature
1P1 Lapshear strength 2000 PSI at R.T.
1P7 Cure hardness of MIL-A-46146
1P8 Condition in container, Dust Free Time, Tack Free Time, Dry Through Time Application
1P9 Viscosity of Base and Catalyst
1R4 Gloss per Batch Acceptance Requirements
1R5 Drying Time per Batch Acceptance Requirements
1R6 Impact Resistance per Batch Acceptance Requirements
1R7 Fluid Resistance per Batch Acceptance Requirements
1R8 Viscosity to be 110 to 150 psi, use Bubble Viscometer from Gardrer.
1S1 Materials consisting of two or more components shall be shelf-life extended and maintained at all times in the form of the original procured kit.
1S3 Standard Cure Time / Curing Rate
1S5 All acceptance tests per specification except for prepreg chemical properties
1S7 A uniform spray pattern with no leakage at the spray nozzle
1S8 Shall be easily mixed by stirring
1S9 Cured hardness per MIL-A-46146, Group I, Type I
1T1 All shelf life extension test per Material Specification
1T3 Test per MIL-C-38334, Type 1
1T4 Bond Shear Strength per Specification
1T5 Storage stability per paragraph 3.7.6 of MIL-T-9906 (Tensile, elongation and initial adhesion testing per ASTM D3330)
1T9 Omit non-volatile content of the thinner
1U1 The curing agent shall be stirred before mixing with sealing compound to verify if it shows signs of settling or hardening. Faillure of the curing agent to return to a smooth, workable consistency shall be construed as a faillure.
1U3 Peel test per BATS 6304, set number 6, immersion (b). Requirement per material spec.
1U4 Peel test per BATS 6304, set number 6, immersion (d). Requirement per material specification.
1U5 Peel test per BATS 6304, set number 7, immersion (d). Requirement per material specification
1U6 Perform the Batch Acceptance Tests required of the manufacturer for Mixed Materials properties only, as per the material specification